gemmh系列堡盟編碼器
voltage supply 10...30 vdc
reverse polarity protection yes
consumption w/o load ≤100ma (24 vdc)
initializing time typ. 250ms after power on
interface canopen®
devicenet
ethernet/ip
profibus-dpv0
profinet
function multiturn
device adress rotary switches in bus cover
steps per revolution ≤8192 / 13bit
number of revolutions ≤65536 / 16bit
absolute accuracy ±0.025°
sensing method optical
code binary
code sequence cw/ccw programmable
interference immunity din en 61000-6-2
emitted interference din en 61000-6-4
programmable
parameters steps per revolution
number of revolutions
preset
scaling
rotating direction
diagnostic function position or parameter error
multiturn sensing
status indicator duo-led integrated in bus cover
approval ul approval / e63076
technical data - mechanical design
size (flange) ø58mm
shaft type ø12mm (through hollow shaft)
ø14mm (through hollow shaft)
protection dinen60529 ip64
operating speed ≤6000rpm (mechanical)
≤6000rpm (electric)
starting acceleration ≤1000u/s²
rotor moment of inertia 20gcm²
material housing: stainless steel 1.4305
flange: stainless steel 1.4305
bus cover: stainless steel 1.4305
operating temperature -25...+85°c
-40...+85°c (optional)
relative humidity 95 % non-condensing
resistance din en 60068-2-6
vibration 10g, 16-2000 hz
din en 60068-2-27
shock 200g, 6 ms
weight approx. 1500g
connection bus cover